Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
    Autoclave 8 Liters Class B with USB Black - My Podologie
    Autoclave 8 Liters Class B with USB Black - My Podologie
    Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
    Autoclave 8 Liters Class B with USB Black - My Podologie
    Autoclave 8 Liters Class B with USB Black - My Podologie
    Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie
Autoclave 8 Liters Class B with USB Black - My Podologie

Product information

Description

Black 8-liter Class B Autoclave with USB

Warranty details.

Safety
- The cycle does not start if the door is not properly closed.
- The automated double hydraulic locking device prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure generator and camera damage.
- A safety thermostat prevents overheating in the chamber and generator.
- An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts electrical power if there is a short circuit or the power supply is unstable.
- Fault alarm indicates a failed cycle and detailed error code.
- Door alarm indicates that the door is not secured.
- Low water alarm indicates when the water tank is empty or overfilled.

Technical Specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- Chamber dimensions: 170 x 320 mm
- Tray size: 130 x 265 mm
- Circuit breaker: F16A / 400V
- 2000W
- Rated power: 1500 VA
- Sterilization temperature: 121 ° C / 134 ° C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 ° C / 40
- Relative humidity: Max. 80%, non-condensing
- External dimensions: 420 x 370 x 525 mm
- Net weight: 37 kg
- Maximum noise level: <70 dB
- Atmospheric pressure from 76 kPa / 106 kPa

Maintenance and error message guide for your sterilizer

Icanclave Autoclave: maintenance and error message guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included accessories
- Sterilizer
- USB
- 2 instrument trays
- Tray support
- Handle for tray extraction
- Door adjustment tool
- 2 drain hoses
- Door seal
- Instruction manual

Regulations
- 93/42 / CEE Medical devices directive.
- 97/23 / CEE Pressure equipment directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Specific requirements for steam sterilizers used for the treatment of medical materials.

Autoclave process step-by-step
1. Open the door, take out the tools and accessories located in the sterilization chamber, remove the packaging and clean them.

2. Plug the power cord into an appropriate power source.

3. Connect the printer (sold separately).

4. Power on: the main switch is located on the front, bottom right of the device. Once switched on, the LCD screen will light up and the basic autoclave operating symbols, such as door position, water level, sterilization program, date, and time will illuminate.

5. Remove the top cover and then fill the distilled water tank. If an audible signal sounds, it means you have exceeded the permitted water level in the tank. Drain the excess water until the alarm turns off.

6. Preparation of material for sterilization: place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all instruments are properly placed, so that no water remains in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the sterilization chamber walls. Do not use paperclips or needles to avoid any damage or malfunction of the autoclave.

7. Select the sterilization program.

8. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the supplied plastic tongs.
Once the instruments are properly placed inside, close the door. Caution: ensure the door is properly closed, otherwise the autoclave will not function.

9. Start the sterilization program.
Press the start button, the autoclave will begin operating for approximately 30-75 minutes.

10. End of sterilization cycle.
Once the sterilization cycle is complete, the printer (not included) will automatically print the full cycle report.
Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will notify you with an audible signal once the sterilization cycle is complete.
Caution: Use plastic tongs to remove the instruments.

IMPORTANT: Do not reuse used water after draining the tank.

It is important to keep the original packaging in case of after-sales service.

Description

Black 8-liter Class B Autoclave with USB

Warranty details.

Safety
- The cycle does not start if the door is not properly closed.
- The automated double hydraulic locking device prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure generator and camera damage.
- A safety thermostat prevents overheating in the chamber and generator.
- An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts electrical power if there is a short circuit or the power supply is unstable.
- Fault alarm indicates a failed cycle and detailed error code.
- Door alarm indicates that the door is not secured.
- Low water alarm indicates when the water tank is empty or overfilled.

Technical Specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- Chamber dimensions: 170 x 320 mm
- Tray size: 130 x 265 mm
- Circuit breaker: F16A / 400V
- 2000W
- Rated power: 1500 VA
- Sterilization temperature: 121 ° C / 134 ° C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 ° C / 40
- Relative humidity: Max. 80%, non-condensing
- External dimensions: 420 x 370 x 525 mm
- Net weight: 37 kg
- Maximum noise level: <70 dB
- Atmospheric pressure from 76 kPa / 106 kPa

Maintenance and error message guide for your sterilizer

Icanclave Autoclave: maintenance and error message guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included accessories
- Sterilizer
- USB
- 2 instrument trays
- Tray support
- Handle for tray extraction
- Door adjustment tool
- 2 drain hoses
- Door seal
- Instruction manual

Regulations
- 93/42 / CEE Medical devices directive.
- 97/23 / CEE Pressure equipment directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Specific requirements for steam sterilizers used for the treatment of medical materials.

Autoclave process step-by-step
1. Open the door, take out the tools and accessories located in the sterilization chamber, remove the packaging and clean them.

2. Plug the power cord into an appropriate power source.

3. Connect the printer (sold separately).

4. Power on: the main switch is located on the front, bottom right of the device. Once switched on, the LCD screen will light up and the basic autoclave operating symbols, such as door position, water level, sterilization program, date, and time will illuminate.

5. Remove the top cover and then fill the distilled water tank. If an audible signal sounds, it means you have exceeded the permitted water level in the tank. Drain the excess water until the alarm turns off.

6. Preparation of material for sterilization: place the instruments on the different trays, separating them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These should not be in contact. Check that all instruments are properly placed, so that no water remains in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the sterilization chamber walls. Do not use paperclips or needles to avoid any damage or malfunction of the autoclave.

7. Select the sterilization program.

8. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the supplied plastic tongs.
Once the instruments are properly placed inside, close the door. Caution: ensure the door is properly closed, otherwise the autoclave will not function.

9. Start the sterilization program.
Press the start button, the autoclave will begin operating for approximately 30-75 minutes.

10. End of sterilization cycle.
Once the sterilization cycle is complete, the printer (not included) will automatically print the full cycle report.
Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will notify you with an audible signal once the sterilization cycle is complete.
Caution: Use plastic tongs to remove the instruments.

IMPORTANT: Do not reuse used water after draining the tank.

It is important to keep the original packaging in case of after-sales service.

Marque : Icanclave Autoclaves  |  Référence : 49.007

Autoclave 8 Liters Class B with USB Black

In short
Class B 8 Litre Black Autoclave with USB backup and double hydraulic lock safety. Delivery only ...  Read more
Regular price
$3,154.00
Sale price
$3,154.00
Regular price
$5,041.00
Shipping calculated at checkout.
🚚 Disponible immédiatement

Disponibilité : actualisez la page une fois la variante sélectionnée pour mettre à jour la disponibilité

Secure Payment: Visa, MasterCard, Amex, Apple Pay
Free delivery from 100€ purchase including tax
Delivery to your office, to a relay point or to your home!

Référence My Podologie : Translation missing: en.products.product.sku:49.007
EAN : 157218610115

Garantie : 1 year
Caractéristiques : Non spécifiées
Mentions particulières : Photos non contractuelles

Check out these similar products