Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
    Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white
Autoclave 23 Liters Class B with USB white

Product information

Description

White 23-liter Class B Autoclave with USB

Warranty details

Safety
- The cycle does not start if the door is not properly closed.
- The automated safety with dual hydraulic locking device prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure generator and camera damage.
- A safety thermostat prevents overheating in the chamber and generator.
- An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off electrical power if there is a short circuit or the power supply is not very stable.
- Failure alarm indicates a failed cycle and the detailed error code.
- Door alarm indicates that the door is not secured.
- Low water alarm indicates when the water tank is empty or overflowing.


Technical Specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- Chamber dimensions: 247 x 450 mm
- Tray size: 192 x 380 mm
- Circuit breaker: F16A / 400V
- 2200W
- Rated power: 1500 VA
- Sterilization temperature: 121 ° C / 134 ° C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 ° C / 40
- Relative humidity: Max. 80%, non-condensing
- External dimensions: 490 x 455 x 690 mm
- Net weight: 53 kg
- Maximum noise level: <70 dB
- Atmospheric pressure from 76 kPa / 106 kPa

Maintenance and error message guide for your autoclave

Icanclave Autoclave: maintenance and error message guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included accessories
- Sterilizer
- USB
- 3 instrument trays
- Tray support
- Handle for tray extraction
- Door adjustment tool
- 2 drain hoses
- Door seal
- Instruction manual

Regulations
- 93/42 / CEE Medical Devices Directive.
- 97/23 / CEE Pressure Equipment Directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 Safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.

Autoclave process step-by-step
1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.

2. Plug the power cord into a suitable power source.

3. Power on: the main switch is located on the front, bottom right of the device. Once turned on, the LCD screen will light up, and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time, will light up.

4. Remove the top cover then fill the distilled water tank. If an audible signal sounds, it means you have exceeded the permitted water level in the tank. Drain the excess water until the alarm turns off.

5. Preparation of material for sterilization: place the instruments on the different trays, and separate them according to their materials. If the instruments are not stainless steel, use sterilization pouches. These should not be in contact with each other. Check that all instruments are properly placed, so that no water remains in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.

6. Select the sterilization program.

7. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the supplied plastic tongs.
Once the instruments are properly placed inside, close the door. Precaution: make sure to close the door properly, otherwise the autoclave will not be able to operate.

8. Start the sterilization program.
Press the start button, the autoclave will begin operating for approximately 30-75 minutes.

9. End of sterilization cycle.
Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.
Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will notify you with an audible signal once the sterilization cycle is complete.
Precaution: Use the plastic tongs to remove the instruments.

IMPORTANT: Do not reuse wastewater after emptying the tank.

 

It is important to keep the original packaging in case of after-sales service.

Description

White 23-liter Class B Autoclave with USB

Warranty details

Safety
- The cycle does not start if the door is not properly closed.
- The automated safety with dual hydraulic locking device prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure generator and camera damage.
- A safety thermostat prevents overheating in the chamber and generator.
- An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off electrical power if there is a short circuit or the power supply is not very stable.
- Failure alarm indicates a failed cycle and the detailed error code.
- Door alarm indicates that the door is not secured.
- Low water alarm indicates when the water tank is empty or overflowing.


Technical Specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- Chamber dimensions: 247 x 450 mm
- Tray size: 192 x 380 mm
- Circuit breaker: F16A / 400V
- 2200W
- Rated power: 1500 VA
- Sterilization temperature: 121 ° C / 134 ° C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 ° C / 40
- Relative humidity: Max. 80%, non-condensing
- External dimensions: 490 x 455 x 690 mm
- Net weight: 53 kg
- Maximum noise level: <70 dB
- Atmospheric pressure from 76 kPa / 106 kPa

Maintenance and error message guide for your autoclave

Icanclave Autoclave: maintenance and error message guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included accessories
- Sterilizer
- USB
- 3 instrument trays
- Tray support
- Handle for tray extraction
- Door adjustment tool
- 2 drain hoses
- Door seal
- Instruction manual

Regulations
- 93/42 / CEE Medical Devices Directive.
- 97/23 / CEE Pressure Equipment Directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 Safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.

Autoclave process step-by-step
1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.

2. Plug the power cord into a suitable power source.

3. Power on: the main switch is located on the front, bottom right of the device. Once turned on, the LCD screen will light up, and the basic operating symbols of the autoclave, such as door position, water level, sterilization program, date, and time, will light up.

4. Remove the top cover then fill the distilled water tank. If an audible signal sounds, it means you have exceeded the permitted water level in the tank. Drain the excess water until the alarm turns off.

5. Preparation of material for sterilization: place the instruments on the different trays, and separate them according to their materials. If the instruments are not stainless steel, use sterilization pouches. These should not be in contact with each other. Check that all instruments are properly placed, so that no water remains in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.

6. Select the sterilization program.

7. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the supplied plastic tongs.
Once the instruments are properly placed inside, close the door. Precaution: make sure to close the door properly, otherwise the autoclave will not be able to operate.

8. Start the sterilization program.
Press the start button, the autoclave will begin operating for approximately 30-75 minutes.

9. End of sterilization cycle.
Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.
Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will notify you with an audible signal once the sterilization cycle is complete.
Precaution: Use the plastic tongs to remove the instruments.

IMPORTANT: Do not reuse wastewater after emptying the tank.

 

It is important to keep the original packaging in case of after-sales service.

Marque : Icanclave Autoclaves  |  Référence : 49.004

Autoclave 23 Liters Class B with USB white

In short
Class B 23 Litre White Autoclave with USB backup and double hydraulic lock safety. Delivery only...  Read more
Regular price
$4,379.00
Sale price
$4,379.00
Regular price
$6,737.00
Shipping calculated at checkout.
🚚 Disponible immédiatement

Disponibilité : actualisez la page une fois la variante sélectionnée pour mettre à jour la disponibilité

Secure Payment: Visa, MasterCard, Amex, Apple Pay
Free delivery from 100€ purchase including tax
Delivery to your office, to a relay point or to your home!

Référence My Podologie : Translation missing: en.products.product.sku:49.004
EAN : 120698927899

Garantie : 1 year
Caractéristiques : Non spécifiées
Mentions particulières : Photos non contractuelles

Check out these similar products